Abstract:
Nowadays, the surgical microscope is the goldstandard for microsurgical procedures. Additional functionalities such as surgical navigation, data injection or imageoverlay are providing additional valuable information to the surgeon. For substituting the conventional optical system by a fully-digital multi-camera setup the three dimensional (3D) reconstruction of the scenery in the field of view is required. However, for in camera-based systems, an exact alignment of the cameras is a challenging task. Therefore, a final adjustment through a digital image rotation becomes necessary. Even though the digital rotation is a commonly used procedure, it leads to unavoidable errors because of the discretized grid of the image. Previous research reported in literature has demonstrated that the method of digitally rotating the images combined with the Fourier interpolation delivers the results of best quality. Nevertheless, the performance evaluation of this algorithm was carried out rotating an image in multiple threestep rotations to a total of 90 or 180 degrees and comparing it to the original image rotated in one step. This is a valid approach because a rotation of 90 or 180 degrees does not produce rotation artifacts. In this research project, we verify the performance of the three-step rotation algorithm using recorded images for which the test pattern was rotated as ground truth. A series of photographs with a rotation angle of 3 to 45 degrees was created. The advantage of this setup is that the result of the digital rotation can be directly compared to the recorded image. In addition, with the knowledge obtained about the interpolation error, we can improve pixel matching in the further triangulation used for 3D reconstruction. By doing so, the estimation of the interpolation error helps to reduce the triangulation error.
Abstract:
Future fully digital surgical visualization systems enable a wide range of new options. Caused by optomechanical limitations a main disadvantage of todays surgical microscopes is their incapability of providing arbitrary perspectives to more than two observers. In a fully digital microscopic system, multiple arbitrary views can be generated from a 3D reconstruction. Modern surgical microscopes allow replacing the eyepieces by cameras in order to record stereoscopic videos. A reconstruction from these videos can only contain the amount of detail the recording camera system gathers from the scene. Therefore, covered surfaces can result in a faulty reconstruction for deviating stereoscopic perspectives. By adding cameras recording the object from different angles, additional information of the scene is acquired, allowing to improve the reconstruction. Our approach is to use a fixed four-camera setup as a front-end system to capture enhanced 3D topography of a pseudo-surgical scene. This experimental setup would provide images for the reconstruction algorithms and generation of multiple observing stereo perspectives. The concept of the designed setup is based on the common main objective (CMO) principle of current surgical microscopes. These systems are well established and optically mature. Furthermore, the CMO principle allows a more compact design and a lowered effort in calibration than cameras with separate optics. Behind the CMO four pupils separate the four channels which are recorded by one camera each. The designed system captures an area of approximately 28mm × 28mm with four cameras. Thus, allowing to process images of 6 different stereo perspectives. In order to verify the setup, it is modelled in silico. It can be used in further studies to test algorithms for 3D reconstruction from up to four perspectives and provide information about the impact of additionally recorded perspectives on the enhancement of a reconstruction.